Calibre UK IC Communication Adapter ICA93LV Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Pompes à eau Calibre UK IC Communication Adapter ICA93LV. Calibre UK IC Communication Adapter ICA93LV User manual [en] Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 15
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Calibre UK Ltd 1999
CALIBRE
I
2
C for Windows 95 Manual
WINI2C/I95
Issue 2.4
16/07/1999
Vue de la page 0
1 2 3 4 5 6 ... 14 15

Résumé du contenu

Page 1 - C for Windows 95 Manual

 Calibre UK Ltd 1999CALIBREI2C for Windows 95 ManualWINI2C/I95Issue 2.416/07/1999

Page 2

CALIBREIssue 2.4Page 716/07/991.9.1.2. An own address of 0 ("general call address") MUST NOT be used as the adapter will go intomonitor mode

Page 3

CALIBREIssue 2.4Page 816/07/991. Check the link configuration of the adapter and also the addresses of other cardswithin your system then re-start the

Page 4

CALIBREIssue 2.4Page 916/07/994. Confirm the comment is to be deleted.1.13.4. To view the data again move the horizontal scroll bar to the left.1.13.5

Page 5

CALIBREIssue 2.4Page 1016/07/99THE MOST COMMONLY ASKED I2C QUESTIONS2.1. General QuestionsQuestion Will my adapter work in a Pentium PC?Answer Yes and

Page 6

CALIBREIssue 2.4Page 1116/07/992.3. WINDOWS 95 and NT QuestionsQuestion My software cannot find the adapter. Your Windows software reports that itcan

Page 7

CALIBREIssue 2.4Page 1216/07/99Send us the following details:-1)The link settings of the adapter.2)A sketch of the relevant I2C hardware including the

Page 8

CALIBREIssue 2.4 Calibre UK Ltd 1999 Page iWelcome to the Calibre I2C for Windows 95 application. This application is designed to allow non-specialis

Page 9

CALIBREIssue 2.4 Calibre UK Ltd 1999 Page iiCONTENTSI2C FOR WINDOWS 95 MANUAL ...

Page 10 - 16/07/99

CALIBREIssue 2.4Page 116/07/99I2C FOR WINDOWS 95 MANUAL1.1. System requirements1.1.1. The software requires a PC with a 386 or better processor, Windo

Page 11

CALIBREIssue 2.4Page 216/07/991.3.4. The Real-Time Bus Monitor cannot be activated from the Windows 95 version, it isrecommended that you run the REAL

Page 12

CALIBREIssue 2.4Page 316/07/991.5.2.2. The parameters displayed in the transfer parameter frame are those relevant to the functionselected (see Functi

Page 13

CALIBREIssue 2.4Page 416/07/991.7.1.2. If the Slave does not require an offset as part of the protocol (See the component datasheet for details) click

Page 14

CALIBREIssue 2.4Page 516/07/991.7.4.3. To start the transfer click on Write.1.7.5. Slave Sender1.7.5.1. Sets up the software as SLAVE (the adapter loc

Page 15

CALIBREIssue 2.4Page 616/07/991.7.6.8. Protocol 2 (as seen from the Master)Slave Write AddressWrite DataStop1.7.6.9. The data received using this prot

Commentaires sur ces manuels

Pas de commentaire